济南俊生建筑工程有限公司为您提供乙级钢质隔热防火门订做。济南防火卷帘门的卷轴故障:
scroll failure of jinan fire shutter door:
1.在使用济南防火卷帘门的时候,卷轴能够转动,但是帘片却怎么也起不来.这种情况的挂钩片断了或者是掉了,需要重新固定,原因则是因为电机跑限位了,维修好就行了.
1 when using the jinan fire shutter doors, the reel to rotate, but the curtain piece but also how to get up. in this case the hook fragment/out, need to be fixed, the reason is because the motor running limit, maintenance is good.
2.如果济南防火卷帘门的帘板新轴上掉下来了:首先我们先将卷帘门的卷轴给放在墙两侧的固定板上,然后再将卷轴上的螺丝给拆卸下来,然后把几块小的帘片给固定在卷帘上,再将卷帘给吊到卷轴上,之后再将几块小的卷帘上的孔和卷轴上的孔给对应着使用螺丝固定好,再将电机把卷帘给卷到一定的位置上,使用电机来调试一下,调试好了就行了.
2 if the jinan fire shutter doors curtain plate new shaft down: first we will reel fixed plate rolling door&put on the wall on both sides,&then scroll on the screws to remove&put a few pieces of small curtain piece fixed to the shutter, the shutter to hang to scroll, then a few small rolling on the hole&the hole on the reel to correspond to use screws fixed, the motor of the curtain to roll to a certain position, use the motor to debug, debugging on the line.
3.济南防火卷帘门在下降停止几个钟之后会自动上升的状况:首先要确定这个卷帘门是不是已经设定了相关的程序是在卷帘门下降几个钟之后自动上升的,或者是说这个工业卷帘门有没有和报警控制盘连接在一起,若是连接的了的话,是不是因为控制盘发出了上升了指令.如果这些都不是的话,那么就可能是济南防火卷帘门的控制键松动了.
3 jinan fire shutter doors will automatically increase the situation after several down to stop clock: first to determine the rolling door is not already set the relevant program is automatically rising after falling several clock in the door,/is that the industrial doors have alarm control panel&connected together, if connected. it is not because of a rise in the control panel instructions. if these are not, then it is the control key jinan fire shutter doors loose